COOLING UNITS
PIPES FOR COOLING UNIT
DCJK
DCJO (Outer pipe)
0 + 0.1
OUT Pipe Connection Part
IN Pipe Connection Part
- 0.1 0
ℓ
D 1
R ( PT )
2
②
ℓ
P
①
④
L
d
D
M Material STPG370 (Sch40)
DCJI (Inner pipe)
ℓ
Outer Pipe (DCJO) Inner Pipe (DCJ I ) Insertion Part
⑤
d D
③
⑥
L
L
① Inside Core
② Cover Case
M Material SUS304
+ 0.1 0 + 0.1 0
6
■ Outer Pipe
+ 0.1 0 + 0.1 0
6
4
Inlay section Diameter D 1
Part Number
4
External diameter D
Internal diameter d
L 5mm increments
Applicable Cooling Units
R (PT)
ℓ
Type
No.
1 2 3
DCJK1 DCJK2 DCJK3
8.9
10.5 13.8 17.3
7.1 9.4
1/8 1/4 3/8
10
DCJO
50—300
12.2 15.7
2
12.7
12
L 2
0 - 0.2
+ 0.2 0
L 1
3
C
C 1
3
L 1
■ Inner Pipe Applicable
Cooling unit components
Part Number
L 5mm increments
External diameter D
Internal diameter d
t
ℓ
① Inside Core Brass (C3604)
② Cover Case Brass (C3604)
③ O–rings
④ O–rings
⑤ Socket Head Cap Screws
⑥ Set screw
Component name
Cooling Units
Type
No.
Fluoric rubber
Fluoric rubber
Stainless steel (SUS304)
Stainless steel (SUS304)
M Material
1 2 3
DCJK1 DCJK2 DCJK3
4 6 8
3 4 6
5
1
Applicable outer pipe
Outer pipe insertion part
Inner pipe insertion part
DCJI
50—300
Part Number
6
2
Applicable inner pipe
B C L
P
ℓ
Hole diameter d 2
Inlay part diameter
Inlay diameter d
Depth
Depth
Type
No.
TYPE
Part Number – L DCJO 1 DCJI 2 – – 100 125
Quotation
Delivery
Order
1 2 3
DCJO 1 8.9 DCJO 2 12.2 DCJO 3 15.7
8.9
DCJI 1 DCJI 2 DCJI 3
4 6 8
24 1820 39 9
DCJK
2
14
12.2 15.7
21 23.5 40 27 30 42
25
10
OUT Pipe
IN Pipe
Detailed dimensions of components Part Number
E Use the outer pipe brazed to the cooling unit. Note the directionality of the inner pipes.
Example
⑤ Socket Head Cap Screws
① Inside Core
② Cover Case
Cooling Unit DCJK
⑥ Set screw
③ O-rings ④ O-rings
C 1
D d d 1
d 2
L 1
L 2
B C
Type
No.
B 1
Outer Pipe DCJO
1 151712 8.9 8 4 3326 1820
ORP 9
ORP 5 CBSS 3– 8 MSSU 3–3 ORP 6 CBSS 4– 8 MSSU 4–4 ORP 10 CBSS 5–10 MSSU 4–4
< Application Table > Cooling Units Outer Pipe Inner Pipe DCJK1 DCJO1 DCJI 1 DCJK2 DCJO2 DCJI 2 DCJK3 DCJO3 DCJI 3
Inner Pipe DCJI
DCJK
2 3
18 20 15 12.2 10 6 34 21 24 18 15.7 13 8 36
21 23.5 ORP 11
27
27 30
ORP 14
Part Number DCJK1
Quotation
Order
Delivery
■ How to Mount • Notch the end face of the inner pipe on the cooling unit side and fix it with set screws facing the cooling water outlet hole side. The inner pipe (DCJI) is notched as standard. • Install the outer pipe, inlet pipe, and outlet pipe by brazing. The end face of the welded side of the outer pipe should be processed to match the inner diameter of the fitting (inlay section processing) before installation. Inlay machining is performed as standard for outer pipe (DCJO). • After fixing the outer pipe to the cooling side, fix the inlet pipe and outlet pipe in the specified position and direction with the fixing bolts. • Be sure to apply grease to the O–ring to protect it during assembly.
1019
1020
E Do not use liquids other than cooling water.