Standard Components For Plastic Mold 2021

MOUNTING JIG FOR TEMPERATURE SENSOR / SHEATH THERMOCOUPLE –SHEATH THERMOCOUPLE (THERMOCOUPLE) / HEAT RESISTANT TYPE–

LEAD WIRE / BAND TEMPERATURE SENSOR FOR HEATER

Sheath thermocouple (thermocouple)

SSM (K type) SSMJ (J type)

Lead wire for heater

Thermocouple category Identification color

Sleeve

Sheath diameter ± 0.05 D

Red ( +) White (-)

Metal protective spring

Y4S Terminal

Packed Product

C

60

L

B

2000

十 Decapod

10PACK–GHRS

一 Monopod

Detection unit

Sleeve heat resistant temperature: 80°C or less E Minimum bending radius ≧ Sheath diameter x 5

Glass fiber coated lead wire

M Material SUS316

Section A (Both ends)

Part Number

Thermocouple Category (Identification color)

Ω/m (Wire resistance value)

Maximum Usage temperature

L 50mm increments

B

C E

Type

D 1

52.0 20.0

500°C 600°C 700°C 750°C 800°C

6.0

1.6 2.3 3.2 4.8

( 7 )

K Type (Blue)

SSM

50–300

35

30

9.8 5.0

L = 1000

8.0

2.25

1

33.6 12.8

6.0

450°C

E 10PACK–GHRS contains 10 pieces. E  The A section is stripped of its coating, but a portion of the coating is left on for workability. The coating can be easily removed by hand.

1.6 2.3 3.2 4.8

J type (yellow)

SSMJ

50–150

35

30

6.3 3.2 1.4

500°C 650°C 750°C

8.0

Lead wire heat resistant temperature: 180 ℃ or less

Red (+) Red (+)

Sleeve Sleeve

Silicon tube Silicon tube

Sheath diameter D ± 0.05 Sheath diameter D ± 0.05

Sheath thermocouple (thermocouple) Heat resistant type

TMK (K type)

Lead wire Nominal cross– sectional area [mm 2 , (sq)]

Maximum wattage used For 100 V For 200 V

Max. operating current (A)

White (-) White (-)

Part Number

L

Type

PACK

No.

0.75 1.25

10 10

20 20

10 10

60 60

0.75 1.25

750

1500 2500 3500

7.5

C C

10PACK

GHRS

1000

1250 1750

12.5 17.5

L L

B B

2000 2000

2

2

+ Decapod + Decapod

Detection unit Detection unit

Part Number – L 10PACK – GHRS 1.25 – 1000

- Monopod - Monopod

Delivery Quotation

■ Heat–resistant Temperature Sleeve: 250°C or less Compensating lead wire: 150°C or less

Order

E Minimum bending radius ≧ Sheath diameter x 5 ※ This product can be used in a high temperature atmosphere.

Silicon tube: 200°C or less M Material Sheath: SUS316 Sleeve: SUS303

E•  When bending the lead wire, leave a margin of 20mm or more from the base. Do not bend the lead wire repeatedly.

Band temperature sensor

Part Number

Thermocouple Category

Maximum Usage temperature

L 50mm increments

B

C

E

Type

D

1.6 2.3 3.2 4.8

650°C 700°C 750°C 800°C

5.0

TMK

50–300

7.0

K Type

36

30

① Tightening band ② Sleeve

SSMB (K type)

9.0

M4 Terminal Red + White -

③ Spring

④ Lead wire

R ( PT ) / 8 1

) / 8

G ( PF

Mounting jig

CSF

1

( 50 )

( 60 )

E  The sleeve part should be used at 90°C or less.

(3)

5

200

35

3000

14

12

Max. operating temperature : 450 ℃

(Sleeve length)

M Material SUS304

5

15

M Material ① SUS304 ② brass (C3604) ③ SUS304

Part Number SSMB30

Part Number

①  By tightening the plug of, the tapered part of the part of ② is tightened, and the sheath part of the thermocouple is bitten and fixed. ② Crush firmly to fix it.

Order

Part Number

Type

D

Example

Type

D

25 30 35 40 45 50

1 1.6 2.3 3.2 4.8 Part Number – L TMK1.6

Delivery Quotation

② ① ③

CSF

SSMB

Mounting hole diameter = sheath diameter + 0.2–0.3

Thermocouple

Mold part

Order

– –

100 50

SSM1 CSF 1

Quotation

Delivery

1075

1076

Powered by