Standard Components For Plastic Mold 2021

FREE WASHERS −PLAIN / FOR COUNTERSUNK BOLT / COUNTERBORED−

For countersunk bolt

Q For heat

Plain

Counterbored

Plain

For countersunk bolt

Counterbored

6.3 ( )

6.3 ( ) 2 - C *

insulation

MWSC (No surface treatment) MWSCN (Electroless nickel plated)

MWFB (No surface treatment) MWFBN (Electroless nickel plated)

MWZC (No surface treatment) MWZCN (Electroless nickel plated)

MWSCS

MWFBS

MWZCS

2 - C *

2 - C *

2 - C *

2 - C *

2 - C *

min.2

min1

2 - C *

2 - C *

D V + 0.1 0 - 0.1 0

0 + 0.1 V 0 - 0.1 D

0 + 0.1 V 0 + 0.1 P 0 - 0.1 D

H T ± 0.1

± 0.1

T ± 0.1 H ± 0.1

D V + 0.1 0 - 0.1 0

0 + 0.1

0 + 0.1 0 + 0.1

V

H T ± 0.1

± 0.1

T ± 0.1 H ± 0.1

± 0.1 T

V P

0 - 0.1 D

± 0.1 T

0 - 0.1 D

Material SUS416

M Material S45C

M

C * c D ≦ 16…C0.1 – 0.3 D > 16…C0.2–0.5

C * c D ≦ 16…C0.1–0.3 D > 16…C0.2–0.5

0.1mm increments

0.1mm increments

Part Number

D

Part Number

D

T

V

P

H

T

V

P

H

5.0–20.0 (0.1mm increments)

5.0–20.0 (0.1mm increments)

Plain MWSC (No surface treatment) MWSCN (Electroless nickel plated)

Plain MWSCS

For countersunk bolt

For countersunk bolt

Plain For countersunk bolt 3.0–70.0

Plain For countersunk bolt 3.0–70.0

0 ≦ H < T E Length of straight section

0 ≦ H < T E Length of straight section

1.0–50.0

1.0–50.0

For countersunk bolt MWFB (No surface treatment) MWFBN (Electroless nickel plated)

Counterbored

only

Counterbored only

For countersunk bolt MWFBS

20.5–60.0 (0.5mm increments)

20.5–60.0 (0.5mm increments)

3.0–68.0

3.0–68.0

Counterbored

Counterbored 1.0 ≦ H ≦ 48.0 E Counterbored depth of bolt head

Counterbored 5.0–70.0

Counterbored 5.0–70.0

1.0 ≦ H ≦ 48.0 E  Counterbored depth of bolt head

Counterbored (D ≧ 10 T ≧ 3.0) MWZC (No surface treatment) MWZCN (Electroless nickel plated)

(D ≧ 10 T ≧ 3.0)

Counterbored

MWZCS

60.5–100.0 (0.5mm increments)

60.5–100.0 (0.5mm increments)

2.0–50.0

2.0–50.0

Counterbored

Counterbored

Plain D > 50 c T ≧ 2: To make D size larger than 50mm, the thickness (T) must be T2 or more. D – V ≧ 2 c The wall thickness must be 1mm or more on each side.

For countersunk bolt D > 50 c T ≧ 2: To make D size larger than 50mm, the thickness (T) must be T2 or more. D – V 2 – (T–H) ≧ 1 c The wall thickness must be at least 1mm.

Plain D > 50 c T ≧ 2: To make D size larger than 50mm, the thickness (T) must be T2 or more. D–V ≧ 2 c The wall thickness must be 1mm or more on each side.

For countersunk bolt D > 50 c T ≧ 2: To make D size larger than 50mm, the thickness (T) must be T2 or more. D–V 2 – (T–H) ≧ 1 c The wall thickness must be at least 1mm.

(D – V)/2 ≧ 1

(D–V)/2 ≧ 1 (V–P) ≧ 2

c The wall thickness must be 1mm or more on each

c The wall thickness must be 1mm or more on each side.

side. (V – P) ≧ 2

c A step of 1mm or more is required on each side. P × 8 ≧ (T–H) ≧ 2 c The bearing bore length (T–H) is between 2mm and P × 8.

c A step of 1mm or more is required on each side. P × 8 ≧ (T–H) ≧ 2 c The bearing bore length (T–H) is between 2mm and P × 8.

PartNumber– D – T – V – P – H MWSCS – D20.0 – T6.0 – V6.0 MWFBS – D20.0 – T6.0 – V6.0 – H3.0 MWZCS – D20.0 – T6.0 – V6.0 – P4.0 – H3.0

Delivery Quotation

Order

PartNumber– D – T – V – P – H MWSC – D20.0 – T6.0 – V6.0 MWFB – D20.0 – T6.0 – V6.0 – H3.0 MWZC – D20.0 – T6.0 – V6.0 – P4.0 – H3.0

Delivery Quotation

Order

SUS416 has low thermal conductivity and is effective in blocking the heat.

Thermal conductivity coefficient [ cal/cm ・ sec ・℃] (100 ℃ )

Thermal expansion coefficient [× 10 – 6 /K( ℃ ) ] (100 ℃ )

Material

Part Number – D – T – V – P – H – (SSC/WSC/TK) MWFBS – D30.0 – T3.0 – V10.0 –H1.0– TK1

Part Number – D – T – V – P – H – (SSC/WSC/TK) MWFB – D30.0 – T3.0 – V10.0 –H1.0– TK1

Alterations

SUS416

0.058 0.120

9.9

Alterations

S50C

11.5 1cal/(cm ・ sec ・℃ ) = 418.6W/(m ・ K)

Alterations Code

Spec.

Alterations Code

Spec.

Alterations Code

Spec.

Alterations Code

Spec.

Changes T dimension tolerance. T ± 0.1 c T + 0.01 0 T dimension can be designated in 0.01mm increments when using TK1 Changes T dimension tolerance. T ± 0.1 c T + 0.02 + 0.01 T dimension can be designated in 0.01mm increments when using TK2 Changes T dimension tolerance. T ± 0.1 c T ± 0.005 T dimension can be designated in 0.01mm increments when using TK3

Changes T dimension tolerance. T ± 0.1 c T + 0.01 0 T dimension can be designated in 0.01mm increments when using TK1 Changes T dimension tolerance. T ± 0.1 c T + 0.02 + 0.01 T dimension can be designated in 0.01mm increments when using TK2 Changes T dimension tolerance. T ± 0.1 c T ± 0.005 T dimension can be designated in 0.01mm increments when using TK3

Cuts a face. SSC = 1mm increments E SSC ≧ V/2 + 2, SSC ≦ D/2−1 X Not available for D5–D8

TK1

Cuts a face. SSC = 1mm increments E SSC ≧ V/2 + 2, SSC ≦ D/2−1 X Not available for D5–D8

TK1

SSC

SSC

SSC ± 0.1

SSC ± 0.1

TK2

TK2

Cuts two faces. WSC = 1mm increments E WSC ≧ V + 4, WSC ≦ D−2 X Not available for D5 – D8

Cuts two faces. WSC = 1mm increments E WSC ≧ V + 4, WSC ≦ D−2 X Not available for D5–D8

WSC

TK

WSC

TK

TK3

TK3

WSC ± 0.1

WSC ± 0.1

Note that designated tolerance of TK alteration is different from that of free washer ( D P.1113 ).

For heat insulation

E

1111

1112

Powered by