Standard Components For Plastic Mold 2021

For heat insulation SUS416

WASHERS (RISER PADS)

URETHANE WASHERS

25

UW

Applicable bolt size d

t

M 6 M 8 M10

6.2 3.5 8.2 4.6 10.2 5.7

E Although urethane itself has a heat resistant temperature of 100°C, when used continuously its durability falls, so use it at a temperature of no more than 80°C.

RPSK (Dowel pin type)

RPST (for countersunk bolt)

RPSB (Bolt fixing type)

C0.3

C0.3

C0.3

C0.3

C0.3

C0.3

V H7

Applicable bolt size d M 6 7 M 8 9 M10 11 M12 13 M16 17

0 - 0.5 + 0.4 + 0.1

8

+ 0.015 0 + 0.018 0

d

10 12 13

0 - 0.3

T

D

H Hardness Shore D58

0 + 0.1

- 0.1 0 0 + 0.1

d

+ 0.2 + 0.1 T ± 0.1 t

V H7

d

- 0.1 0

■ Urethane hardness characteristics comparison (comparison with Shore A95) Characteristics Unit Shore D58

+ 0.1 + 0.2

+ 0.1 + 0.2

D

- 0.1 0

Part Number

T

T

D

D

D

d

T

Type

d

M Material SUS416

M Material SUS416

M Material SUS416

Shore A95

10 13 16 20

16 18 24 27

10 13 16 20

Tensile Strength

MPa

47.8

39.2

Part Number

Part Number

Part Number

Applicable bolt size (M) Selection

Applicable bolt size (M) Selection

V

T

T

T

Elongation

440 153

400 107

Type

D

Type

D

Type

D

1.5 3

UW

Tensile Breakage Strength Impact Resilience Compression Set Heat–resistant Temperature

kgf/cm

25

8 10

25 6 8 10

30

6

8

% % ℃

53 39

40 45

10 15 20

RPST

10 15 20

10 15 20

100 80 E The above value is the reference value. It is not a guarantee value.

RPSK

RPSB

40

6

8

10

30

8 10 12

30

8 10 12 16

Part Number – T UW10 – 1.5

Order

40

10 12

13

40

8 10 12 16

Stop bolt STBG ( P.915 )

UW

Quotation

Part Number – V/M – T RPSK30 – V12 – T15 RPSB40 – M12 – T20

Delivery

Applicable bolt size d d 1

h M 6 6.2 11 6.5 M 8 8.2 14 8.6 M10 10.2 17.5 10.8 M12 12.2 20 13

Order

Fixed side molding plate Runner stripper plate Selection side plate

Example Use for sound proofing when the mold is being opened.

Delivery Quotation

RPSZ (Counterbore type)

d 1

C0.3

C0.3

Fixed side molding plate

Part Number – V,M – T –

(MK/TK1/TK2/TK3)

Puller bolt PBTN ( P.917 )

Alterations

UW

MK

RPSZ30 – M8 – T15 –

Alterations Code

Spec.

Adds a groove on both sides in order to facilitate insulation. X Express services not available

●  When using a urethane washer on the stopper bolt, be careful of the forming dimension of the counterbore depth (W) for securing the stroke (S). ●  The dimension of the stopper bolt is set so that the head is recessed 2mm below the mounting plate. (See "Stopper Bolt STBG" on P.915 .) When using a urethane washer, the relationship between the counterbore depth (W) and the stroke (S) is [W = S + Urethane Washer Thickness T + stopper bolt head thickness K + 2].

2

2

Runner stripper plate

0 + 0.1

d

+ 0.1 + 0.2 T ± 0.1 h

0 D

- 0.1

MK

M Material SUS416

RPSK/RPSB RPST E Forming marks sometimes remain on the bottom face of the formed groove. RPSZ

Part Number

Applicable bolt size (M) Selection

T

Changes T dimension tolerance. Code

Type

D

E All pieces are grinded together when 20 pieces or less are ordered. (Although T dimension tolerance is as stated in the left table, variation will be limited within 0.01.)

TK1 TK2 TK3

T Tolerance T

Selection side plate

+ 0.02 0 ± 0.01

25

6

TK1 TK2

10 15 20

0 –0.02

T

TK3

6

30

E Note that designated tolerance of TK alteration is different from that of free washer ( D P.1097 ), For heat insulation and free washer ( D P.1098 ).

15 20 10 15 20

RPSZ

8 10

■ Stopper bolt STBG (P.915) K size table STBG Shaft diameter D Head thickness K 10 8 13 8 16 13 20 13

6

40

15 20 12 20

8 10

RPST

UW

Example

SUS416 has low thermal conductivity and is effective in blocking the heat.

Thermal expansion coefficient [× 10 – 6 /K( ℃ ) ] (100 ℃ )

Thermal conductivity coefficient [ cal/cm ・ sec ・℃] (100 ℃ )

Material

RPSZ

RPSK

RPSB

SUS416

0.058

9.9

S50C

0.120

11.5

1cal/(cm ・ sec ・℃ ) = 418.6W/(m ・ K)