〔 PRODUCT DATA 〕 GRAPH OF FLOW RATE AND PRESSURE LOSS CHARACTERISTICS FOR COUPLERS / SOCKETS FOR COOLING ①

〔 PRODUCT DATA 〕 FLOW RATE WHEN 98KPA FOR COUPLERS / SOCKETS / PLUGS FOR COOLING

■ Single Valve Type Flow Rate when 98kPa ( L/min. ) E Single valve type is of the couplers series, which has an automatic open/close valve only on the socket side.

■ Graph of Flow Rate and Pressure Loss Characteristics

Mold Couplers

High Coupler for Cooling Water Pipe

Large Flow Mold Couplers

Mold Coupler Series

High Coupler Series for Cooling Water Pipe

Large Flow Mold Couplers Series

70 60 50 40 30 20 10 0

1000

1000

1000

L (Liter)

K3 - KSH3 × K3 - KPM3

KSH3 × KPM3

Flow rate

KSH2 × KPM2

KHSH2 × KHPM2

KHSH3 × KHPM3

100

100

100

KSH2 × KPM2 KSH3 × KPM3

KHSH2 × KHPM2 KHSH3 × KHPM3 High Coupler Series for Cooling Water Pipe

K3–KSH3 × K3–KPM3 K4–KSH4 × K4–KPM4

Mold Coupler Series

Large Flow Mold Couplers Series

Sockets Plugs Connection hole diameter 8mm/Plug diameter 8mm Applications

Sockets Plugs Connection hole diameter 10.9mm/Plug diameter 10.9mm common Applications

Applications

10

10

10

Sockets Plugs Connect by matching the size of hole diameter with the plug diameter

K4 - KSH4 × K4 - KPM4

1

1

1

1

10

100

100

1

10

100

1

10

Flow rate Q [L/min . ]

Flow rate Q [L/min . ]

Flow rate Q [L/min . ]

■ Valveless Type Flow Rate when 98kPa ( L/min. ) E Valveless type is a coupler series in which there is no automatic open/close valve in either the socket or plug.

Compact double valves Cooling High Flow Couplers Series

Valveless TSP Coupler Series for Cooling

Double valves SP Coupler Series for Cooling

Mold Couplers (No valve)

TSP Couplers for Cooling

70 60 50 40 30 20 10 0

1000

1000

1000

L (Liter)

F120 - SF3 × F120 - PF3

F120 - HFLS4 × F120 - HFLP4

F120 - TSF4 × F120 - TPF4

F120 - HFLS3 × F120 - HFLP3

Flow rate

F120 - TSF3 × F120 - TPF3 F120 - TSF2 × F120 - TPF2

F120 - HFLS2 × F120 - HFLP2

F120 - SF2 × F120 - PF2

100

100

100

F120–TSF2 × F120–TPF2 F120–TSF3 × F120–TPF3 F120–TSF4 × F120–TPF4

KTSH2 × KPM2

KTSH3 × KPM3

SF120 - SF4 × SF120 - PF4 F120 - SF4 × F120 - PF4

Mold Coupler Series

Valveless TSP Coupler Series for Cooling

10

10

10

Applications

Applications

Sockets Plugs Connect by matching the size of hole diameter with the plug diameter

Sockets Plugs Connection hole diameter 8mm/Plug diameter 8mm

1

1

1

1

10 100 Flow rate Q [L/min . ]

1000

1

10

100

100

1

10

Flow rate Q [L/min . ]

Flow rate Q [L/min . ]

■ Double Valves Type Flow Rate when 98kPa ( L/min. ) E Double valves type is a coupler series in which there is automatic open/close valve in socket and plug respectively.

JPS ( Mold Couplers/Plugs )

JPL ( High Couplers for Cooling Water Pipe/Plugs ) JPJ ( Joints for Cooling Water/Plugs )

SP Couplers for Cooling

Cooling High Flow Couplers

70 60 50 40 30 20 10 0

kPa 〔 kgf/cm 〕 2

kPa 〔 kgf/cm 〕 2

kPa 〔 kgf / cm 〕 2

L (Liter)

〔 0 . 5 〕 〔 0 . 1 〕 〔 0 . 3 〕 〔 0 . 05 〕 〔 0 . 03 〕 〔 3 . 0 〕 〔 1 . 0 〕

〔 0.5 〕 〔 0.1 〕 〔 0.3 〕 〔 0.05 〕 〔 0.03 〕 〔 3.0 〕 〔 1.0 〕

〔 0 . 5 〕 〔 0 . 1 〕 〔 0 . 3 〕 〔 0 . 05 〕 〔 0 . 03 〕 〔 3 . 0 〕 〔 1 . 0 〕

Flow rate

294

294

294

JPS1 JPS2 JPS3

JPL2/JPL3 JPL1

JPJ1 JPJ2 JPJ3

49 . 0 2 . 94 4 . 9 9.8 29 . 4 98 . 0

49 . 0 29 . 4 98 . 0

29 . 4 49 . 0 98 . 0

2 . 94 4 . 9 9 . 8

2 . 94 4 . 9 9 . 8

F120–SF2 × F120–PF2 F120–SF3 × F120–PF3 F120–SF4 × F120–PF4

F120–HFLS2 × F120–HFLP2 F120–HFLS3 × F120–HFLP3 F120–HFLS4 × F120–HFLP4

Double valves SP Coupler Series for Cooling

Compact/Double valves Cooling High Flow Couplers Series

0 . 98

0 . 98

0 . 98

Applications

Applications

1

3 5

10

30 50

100

1

3 5

10

30 50

100

1

3 5 10

30 50 100

〔 L / min. 〕

〔 L / min. 〕

〔 L/min. 〕

Flow rate Q →

Flow rate Q → (When connecting DME AJS203V (PT1/4))

Flow rate Q →

Sockets Plugs Connect by matching the size of hole diameter with the plug diameter

Sockets Plugs Connect by matching the size of hole diameter with the plug diameter

(When connecting KSH2)

(When connecting KSH2)

E Graphs of flow rate and pressure loss indicate the flow rate Q (L/min.) and pressure loss ⊿ P when the cooling water flows. (Fluid used during measurement: water, Water temperature: room temperature, Direction of flow: socket → plug) E Shown values are the examples of measurement values and are not guaranteed values.

E Graphs of flow rate for 98kPa indicate the flow rate in 1 minute in L (liter) when the cooling water flows under the hydraulic pressure of 98kPa (about 1kgf/cm 2 ) (Fluid used during measurement: water, Water temperature: 10°C ± 3°C, Direction of flow: socket → plug) E Shown values are the examples of measurement values and are not guaranteed values.