Standard Components For Plastic Mold 2021

NAK80 DH2F

STRAIGHT CORE PINS WITH GAS VENT –SHAFT DIAMETER (D) SELECTION TYPE / SHAFT DIAMETER (P) 0.01mm DESIGNATION TYPE–

SKD61 SKH51

DC (DCX) PC (PCX)

Type

T Tolerance D/DC/P/PC

Part Number – L – P –

– N – SV

M Material H Hardness

Order

Shaft Diameter (D) selection Shaft Diameter (P) designation GV–CPN–L GV–CPNB–L GV–CPF–L GV–CPFB–L GV–CPD–L GV–CPDB–L GV–CPX–L GV–CPXB–L GV–CPK–L GV–CPKB–L GV–CPG–L GV–CPGB–L GV–CPP–L GV–CPPB–L GV–CPH–L GV–CPHB–L

GV– CPX–L1 – 20.05 – N2 – SV4 GV–CPHB–L3 – 18.36 – P2.96 – PC2.950 – N2 – SV4

NAK80

37–43HRC 38–42HRC 48–52HRC 58–60HRC 37–43HRC 38–42HRC 48–52HRC 58–60HRC

DH2F

–0.01 –0.02

SKD61 SKH51 NAK80

Delivery Quotation

DH2F

0 –0.005

SKD61 SKH51

Part Number – L – P – DC (DCX) PC (PCX)

– N – SV (SVC) – (KC/WKC … etc.)

Alterations

GV–CPH –L3 – 18.36 – DCX – N2 – SVC – WKC1.5 GV–CPHB–L3– 18.36 – P2.96 – PCX – N2 – SVC – WKC1.48

D a 0.5– 0.9 0.50– 0.99 (D or P) –0.1 0.05 1 – 2.5 1.00– 2.49 (D or P) –0.2 0.10 3 – 4 2.50– 3.99 (D or P) –0.4 0.20 4.5 / 5 4.00– 4.99 (D or P) –0.6 0.30 6 – 13 5.00–12.99 (D or P) –1.0 0.50 P d

Alteration details D P.323

Alterations Code

Spec.

Alterations Code

Spec.

Head diameter change HC = 0.1mm increments E (D or P) ≦ HC < H E In relation to the head diameter tolerance, alteration may create a straight piece with little diameter difference between the head and shaft.

0.5

0.2

2

0 SV

0 N

HC

About Designation Unit for Key Flat Cutting

R ≦ 0.3

Single flat cutting (D or P)/2 ≦ KC < H/2 (D or P) ≧ 0.6

KC

Head diameter change (precision) HCC = 0.1mm increments E  (D or P) + 0.5 ≦ HCC < H–0.3, (D or P) ≧ 0.6

0 - 0.01 KC

HCC

(1) To align the key flat

with the shaft diameter

Unit of designation Shaft Diameter (D) selection 0.05mm increments possible Shaft Diameter (P) designation 0.005mm increments possible

0 - 0.02

• Shaft diameter (D) selection D TC 0.5 ≦ D < 0.8 2.0 ≦ TC < 4.0 0.8 ≦ D ≦ 13 1.5 ≦ TC < 4.0 • Shaft diameter (P) designation P TC 0.50 ≦ P < 0.80 2.0 ≦ TC < 4.0 0.80 ≦ P ≦ 12.99 1.5 ≦ TC < 4.0

T = 4

Head thickness change TC = 0.1mm increments (Dimension L remains unchanged) E 4–TC ≦ Lmax.–L

+ 0.02 0

L

E When (D or P) –0.01

–0.02 Shaft diameter selection: DC designation not available. DC = D Shaft diameter designation: PC designation not available. PC = P

0

TC

TC

- 0.02

4

Two flats cutting (D or P)/2 ≦ WKC < H/2 (D or P) ≧ 0.6

■ Shaft Diameter (D) Selection Type

WKC

Part Number

0 - 0.01 WKC

Relief under the head (No need for plate chamfering) Available when (D or P) ≧ 0.6

L 0.01mm increments

DC 0.005mm increments

N 0.1mm increments

SV 0.5mm increments

H

TRN

Type

D

GV–CPX–L GV–CPH–L GV–CPN–L (D ≧ 0.8) GV–CPF–L (D ≧ 0.8) GV–CPD–L GV–CPX–L GV–CPK–L (D ≧ 0.8) GV–CPG–L (D ≧ 0.8) GV–CPP–L GV–CPH–L

Numbering at the back part of the head Range of designation and Designation method D P.324 E Available when H ≧ 2 Process the SV part till the head end face. E Only available for GV–CPN–L/GV–CPK–L GV–CPNB–L/GV–CPKB–L when (D or P) ≧ 2 E (D or P) < 1 c L = Applicable until 60 E When used concurrently with key flat cutting, SVC processing is done perpendicularly to the key flat surface.

(2) To designate arbitrary key flat dimensions Unit of designation 0.1mm

0.5 0.6 0.7 0.8 0.9 1 1.2 1.5

15.00–60.00

2

A15

NHC

8

Varied width parallel flats cutting (D or P)/2 ≦ KAC < H/2 KBC = 0.1mm increments only (D or P) ≧ 0.6 KAC < KBC < H/2

KAC KBC

3

0.3–10.0

2.0–50.0

0 - 0.01 0 - 0.01

KBC

15.00–100.00

(D–0.08) ≦ DC ≦ D E When D –0.01 –0.02 DC not available

SVC

L– (2 + SV + N) ≧ 10

KAC

SVC

2

4 5 6 7 8 9

2.5

3

■ Features For molds using resin that generates gas easily, this core pin has the effect of releasing gas from the inside of the cavity through the core pin clearance.

E  When DC = D,

3.5

designation of DCX

4

4.5 5

Example

15.00–120.00

0.5–15.0

2.0–60.0

6 7 8

10 11 15 18

1. Assemble at the surface of product to release gas. 2. Assemble in the place where the gas gathers in the runner part, and release gas.

L– (2 + SV + N) ≧ 10

10

13 ■ Shaft Diameter (P) Designation Type

Gas is released from the clearance. Please set clearance to include the way of gas-flow according to resin and molding condition (Designate on DC/PC). ※ Gas flow Gas is released from the clearance. Please set clearance to include the way of gas-flow according to resin and molding condition (Designate on DC/PC). ※ Gas flow

0.01mm increments

Part Number

PC 0.005mm increments

N 0.1mm increments

SV 0.5mm increments

H

Molding products

Molding products

Type

No.

L

P

GV–CPXB–L GV–CPHB–L GV–CPNB–L (P ≧ 0.80) GV–CPFB–L (P ≧ 0.80) GV–CPDB–L GV–CPXB–L GV–CPKB–L (P ≧ 0.80) GV–CPGB–L (P ≧ 0.80) GV–CPPB–L GV–CPHB–L

0.6

0.50– 0.59 0.60– 0.99 1.00– 1.49 1.50– 1.99 2.00– 2.49 2.50– 2.99 3.00– 3.49 3.50– 3.99 4.00– 4.49 4.50– 4.99 5.00– 5.99 6.00– 6.99 7.00– 7.99 8.00– 9.99 10.00–12.99

3

1

1.5

15.00–100.00

0.3–10.0

2.0–50.0

2

4 5 6 7 8 9

(P–0.08) ≦ PC ≦ P E When P –0.01 –0.02 PC not available E  When PC = P, designation of PCX

L– (2 + SV + N) ≧ 10

2.5

3

3.5

4

4.5

5 6 7 8

15.00–120.00

0.5–15.0

2.0–60.0

10 11 15 18

Please use SVC alteration when processing plate by wire cutting. < Alteration SVC >

< Alteration WKC >

Please use SVC alteration when processing plate by wire cutting. < Alteration SVC >

< Alteration WKC >

L– (2 + SV + N) ≧ 10

10 13

463

464

Powered by