HPM1 equivalent SKD61 DC53
SPRUE BUSHINGS P3.5 SR11 –NORMAL BOLT TYPE / FLANGE THICKNESS 10MM / L DIMENSION SELECTION TYPE–
E This product is a standardized version of the most frequently specified size for the dimension free type on P.679. Finish L dimension before use.
–Straight Type–
Part number – L (LC) – A – (AIW/AXW … etc.) SBBK–B16 – LC78.5 – A3 – AIW10–GC7
Part number
Alterations
M Material
H Hardness
Normal String Eliminator Type SBBP–B SBBPH–B SBBK–B SBBKH–B SBBS–B SBBSH–B
Quotation
HPM1 equivalent
37–43HRC
SKD61
48–52HRC
Spec.
Alterations
Codes AIW AHW AXW ATW AJW ALW APW
DC53
58–62HRC
Runner grooving shape A (Trapezoid)
• W dimension and GC°selection W t GC° 3 2.5 7°
+
+
+
+
+
+
+
Designation method AIW10−GC7 + Bolt hole position KC position (When KC code is used)
Spec.
GC °
+
+
+
+
+
+
+
3
4 3 5 3.5 6 4 8 5.5
R0.5
2 - R4.5
Part C
E Can be designated only when using LC/LKC. E ATW, AJW, ALW and APW have working limits as follows. when D = 10, ( α −0.6) ≧ W when D ≧ 13 ( α −0.4) ≧ W E The trapezoidal taper angle, which was previously fixed at 10°, is now selectable from 10°and 7°. Designation method AHW4–GC7 Specify in the sequence "(shape) (W dimension)–GC°." If the angle is not specified, (AHW4, for example) it will be considered as 10°. 10° 10 7
G
1.6
t
1.6
Spec.
Alterations
Codes BIR BHR BXR BTR BJR BLR BPR
Runner grooving shape B (Semicircle)
Details of Part C
+
+
+
+
+
+
+
• R dimension selection 1 1.25 1.5 1.75 2 2.25 2.5 3 3.5 4
Designation method BXR2 + Bolt hole position KC position (When KC code is used)
Spec.
5.5
D
R0.5
h6
+
+
+
+
+
+
+
+ 5 + 0.1
0 - 0.2
L
± 0.1
10
40
R
E Can be designated only when using LC/LKC. E Code BTR, BJR, BLR and BPR have working limits as follows. when D = 10, ( α –0.6) ≧ 2 × R when D ≧ 13, ( α −0.4) ≧ 2 × R
3
a Fittings CB5–12 (2 pcs.) E Check catalog page ( D P.675 ) for details on String Elimination.
Spec.
Alterations
Codes CIQ CHQ CXQ CTQ CJQ CLQ CPQ
Runner grooving shape C (Arc + Tangent)
+
+
+
+
+
+
+
• Q dimension selection 2 2.5 3 3.5
Designation method CTQ5 + Bolt hole position KC position (When KC code is used)
Spec.
Part number
L
A°
D h6
+
+
+
+
+
+
+
Type
D
5 °
E Can be designated only when using LC/LKC. E Code CTQ/CJQ/CLQ/CPQ have working limits as follows. when D = 10, ( α −0.6) ≧ Q × 1.09 when D ≧ 13, ( α –0.4) ≧ Q × 1.09
4 5 6 8
–Straight Type–
0 –0.009
10 30 40 50 60 80
2
3
10
Q
Normal
String Eliminator Type
(HPM1 equivalent) SBBP–B SBBPH–B
Alterations Codes
Spec.
Alterations Codes
Spec.
13
13
SBBK–B SBBKH–B
Single flange cutting KC = 0.5mm increments D/2 ≦ KC < 20
(SKD61)
Full length alteration LC = 0.1mm increments E L dimension can be designated at 0.01mm increments when LKC is used E 30 ≦ LC ≦ 80 When LC is used L + 5 + 0.1 c L + 0.1 0
0 –0.011
30 40 50 60 80
2
3
KC
SBBS–B SBBSH–B
(DC53)
LC
0 - 0.1
X Not available for string eliminator type E Interference with the SR part may occur.
KC
16
16
LC
Two parallel flange cutting WKC = 0.5mm increments D/2 ≦ WKC < 20
° Conversion Chart of Trigonometric Functions D P.1215
( * 1) (Calculation of α value) α= 3.5 + 2 (L + 7) tan A – 2 E Similar standards: free designation type D P.679
WKC
Total length tolerance alteration L + 5 + 0.1 c L 0 –0.02
0 - 0.1
X Not available for string eliminator type E Interference with the SR part may occur.
WKC
LKC
E LC not available when L30, L40, L50, L60, or L80 is selected. E Applicable only to LC designated dimensions and L30, L40, L50, L60, L80
L
Part number – L – A SBBP–B10 – 40 – A3
Order
Delivery Quotation
677
678
Powered by FlippingBook