Standard Components For Plastic Mold 2021

STOP BOLTS/URETHANE WASHERS

Packed Product

■ Stopper Bolt Selections

M (Coarse thread)

Stop Bolts

STBG

G

1.6

• Using the table below, select the appropriate stopper bolt size in accordance with the thickness of the fixed installation plate and runner stripper plate to be used.

Runner stripper plate thickness 10 15 20 25 30 35 40 50

Runner stripper plate thickness 10 15 20 25 30 35 40 50

Fixed installation plate thickness

Stopper bolts D

Stopper bolts D

Fixed installation plate thickness

L

E

L

E

20 101924–––––– 25 15 192429– – – – – 30 20 19242934 – – – – 20 102227–––––– 25 15 22273237 – – – – 30 20 2227323742 – – – 35 25 – 27323742 – – – 40 30 – 2732374247 – – 45 35 – – –374247– – 25 10 –3035– – – – – 30 15 –303540– – – – 35 20 – 30354045 – – – 40 25 – 3035404550 – – 45 30 – – 3540455055 – 50 35 – – – –455055–

30 15 – –3843– – – – 35 20 – –384348– – – 40 25 – – 38434853 – – 45 30 – – – –485358– 50 35 – – – –485358– 60 45 – – – – –5358– 35 15 – –4449– – – – 40 20 – – –495459– – 45 25 – – –495459– – 50 30 – – – 49545964 – 60 40 – – – – 54596469 45 25 – – –556065– – 50 30 – – – 55606570 – 60 40 – – – – 60657080 70 50 – – – – 60657080

B H

C

10

- 0.2 L 0

E

e9 D

K

20

M Material SCM435 H Hardness 33–38HRC

13

Part Number

C K H B M

L

E

Type

D

10 19 24 15 19 24 29 20 19 24 29 34 10 22 27 15 22 27 32 37 20 22 27 32 37 42 25 27 32 37 42 30 10 30 35 15 30 35 40 20 30 35 40 45 25 30 35 40 45 50 30 35

25

10

4

8

16

6

6

17

16

30

13

4

8

18

8

8

20

27 32 37 42 47

Urethane Washers

37 42 47

UW

E Although urethane itself has a heat resis- tant temperature of 100°C, when used continuously its durability falls, so use it at a temperature of no more than 80°C.

16

7

13

24

10

10

23

35 40 45 50 55

35

45 50 55

STBG

15 38 43 20 38 43 48 25 38 43 48 53 30

0 - 0.5 + 0.4 + 0.1

d

0 - 0.3

H Hardness ShoreD58

T

D

20

9

13

27

14

12

26

48 53 58 48 53 58

■ Urethane hardness characteristics comparison (comparison with Shore A95)

35 45

Part Number

D

d

T

53 58

Type

d

Characteristics

Unit

ShoreD58

ShoreA95

15 44 49 20

10 13 16 20

16 18 24 27

10 13 16 20

Tensile Strength

MPa

47.8

39.2

49 54 59 49 54 59

1.5 3

Elongation

%

440 153

400 107

25 30 40

25

10

18

33

17

16

32

UW

kgf/cm

Tensile Breakage Strength

49 54 59 64

54 59 64 69

Impact Resilience Compression Set

% %

53 39

40 45 80

25 55 60 65 30 55 60 65 70 40

Part Number – T UW10 – 1.5

Heat–resistant Temperature

100

30

10

18

40

17

20

38

Order

60 65 70 80 60 65 70 80

50

E The above value is the reference value. It is not a guarantee value.

Part Number – L – E STBG16 – 20 – 30

Quotation

Delivery

Order

• When using a urethane washer on the stopper bolt, be careful of the forming dimension of the counterbore depth (W) for securing the stroke (S).

Example

Use for soundproofing when the mold is being opened.

Quotation

Delivery

UW

Stop bolt STBG

• The dimension of the stopper bolt is set so that the head is recessed 2mm below the mounting plate.(See left page for "Stopper Bolt STBG") When using a urethane washer, the relationship between the counterbore depth (W) and the stroke (S) is [W = S + Urethane Washer Thickness T + stopper bolt head thickness K + 2].

• Shaft diameters ( D P.917 ) for stopper bolts STBG and puller bolts PBTN are identical and can be used in combination. When using a D20 stopper bolt, use it together with a D20 puller bolt. • The stopper bolts are designed to sink 2mm from the surface of fixed installation plates listed in the right table. Therefore, the relationship between the counterbore depth (W) and stroke (S) is: [W = S + Stopper bolt’s head thickness K] + 2

Stop bolt

Example

Fixed installation plate Runner stripper plate

Fixed installation plate Runner stripper plate

Fixed die plate

Puller bolt PBTN ( P.917 )

Fixed die plate

L = (Fixed installation plate thickness) – (Stopper bolt's head thickness K + 2)

Part Number

T

PACK

Type

d

Packed Product

Puller bolt

10PACK

UW

10 13 16 20 1.5

3

Fixed installation plate

Information on packing sales It is advantageous to buy the same size in bulk.

• When a runner stripper plate thickness in the following table is used, screw length ℓ for the stopper bolt is designed to fit into the puller bolt in a length of 1.5 times longer than the screw diameter. In this state, the stopper bolt's thread has an 8mm part not fit into the puller bolt so that a counterbore can be created on the runner stripper plate to house a spring.

Runner stripper plate

Part Number

T

Quotation

Delivery

Order

Spring

PACK Type 10 PACK–UW10–

Fixed die plate

1.5

E = (Stopper bolt M diameter) × 1.5 + (Runner stripper thickness)

915

916