Standard Components For Plastic Mold 2021

TENSION LINKS –LONG STROKE TYPE–

TENSION LINKS –ADJUSTABLE STROKE TYPE–

TLK TLKH

TLW TLWH

( R )

( R )

4 - C1 - 3

4 - C1 - 3

S ± 0.1 L + 0.3 0

± 0.1 S

T ± 0.1

e

0 + 0.3

L

( TLK )

( TLW )

2 - C3

2 - C3

( TLKH )

( TLWH )

4 - C3

4 - C3

M Material S45C

M Material S45C

Part Number

5mm increments

Part Number – L – S – T TLWH25 – 260 – S100 – T100

Part Number – S TLK25 – 100

Part Number

e min.

S 5mm increments

B

B ℓ

L

Order

Order

Type

Type

L

S

T

A

A

19 100—320 15—130 40—140 25 115—335 15—135 40—140 32 140—385 25—140 50—180 38 150—410 25—150 50—185

25 25 28 34

11 15

S + 29 S + 34 S + 37 S + 41

19 25 32 38

50—230 ( 250 ) 50—270 ( 300 ) 80—350 ( 400 )

11 14 17 21

14.5

TLW TLWH

14 17.5 17 18.5 21 20.5

TLK TLKH

17

Quotation

Quotation

Delivery

Delivery

18.5 20.5

E L–2ℓ–S–T ≧ e min.

100—400 ( 450 ) E The figures in ( ) are applicable for TLK only.

Part Number – (SC) TLK25 – SC97 Alterations

Part Number – L – (SC) – (TC) TLWH 25 – 260 – SC98 – TC96

Alterations

Alterations

Spec.

Alterations

Code

Spec.

Code

SC = 1mm increments

SC designation range

E

SC designation range

A e min. E

Part Number

SC = 1mm increments E L–2ℓ–SC–T (TC) ≧ emin. E e min. changes to the value shown in the table at right. TC = 1mm increments E L–2ℓ–S (SC)–TC ≧ emin. E e min. changes to the value shown in the table at right.

50 < SC < 230 (250) 50 < SC < 270 (300) 80 < SC < 350 (400)

TLK/TLKH19 TLK/TLKH25 TLK/TLKH32 TLK/TLKH38

15 < SC < 130 15 < SC < 135 25 < SC < 140 25 < SC < 150

19 25 32 38

22 25 28 34

SC

SC

± 0.1 SC

SC ± 0.1

100 < SC < 400 (450) E The figures in ( ) are applicable for TLK only.

TC designation range

A e min. E

■ Example of Mounting TLK/TLKH

Fig. 1 Mold closed

Fig. 2 Mold opened

40 < TC < 140 40 < TC < 140 50 < TC < 180 50 < TC < 185

19 25 32 38

22 25 28 34

TC

Example

• When using the special retainer (LKT)

TC ± 0.1

LKT (

) P.940

• Not being fixed on the plates with bolts, this tension link –long stroke type– will be in the state as shown in Fig. 1 when mold closes. It enables to secure a longer stroke and to keep the mold height low. • When special bolt (LKB/LKBH), retainer (LKR/LKRH), (LKT) for links are used in fixing tension links, accidents such as damage can be prevented. LKB / LKBH, LKR / LKRH, LKT D P.940 • When special retainer (LKT) is used, head section of the retainer makes a 1mm clearance and mold can be opened and closed without having link and plate in contact.

TLK

■ Example of Mounting TLW/TLWH • When using the special retainer (LKT)

Example

• When using the special retainer (LKR/LKRH)

※ When installing the TLKH, use it with a 3mm counterbore.

LKT (

) P.940

LKR / LKRH (

P.940 )

TLW

• When using the special retainer (LKR/LKRH)

TLW

LKR / LKRH (

) P.940

TLK

※ When installing the TLKH, use it with a 3mm zagging.

※ When installing the TLWH, use it with a 3mm counterbore.