Standard Components For Plastic Mold 2021

Compact/Double Valves Cooling High Flow Couplers Series

Compact/Double Valves Cooling High Flow Couplers Series

COMPACT/ DOUBLE VALVES COOLING HIGH FLOW COUPLERS –STAINLESS STEEL SOCKETS/PLUGS– –HEAT RESISTANT 180°C SERIES–

COMPACT/ DOUBLE VALVES COOLING HIGH FLOW COUPLERS –SOCKETS/PLUGS– –HEAT RESISTANT 180°C SERIES–

Sockets Plugs Connect by matching the hole diameter with the plug diameter Suitable

Sockets Plugs Connect by matching the hole diameter with the plug diameter Suitable

E Use cooling high flow coupler series matching with the diameter size of socket and plug. Please note it's not applicable to combining different sizes.

E Use cooling high flow coupler series matching with the diameter size of socket and plug.

For male screw joint F120–HFLS (Brass)

For male screw joint SF120–HFLS (Stainless Steel)

※ Plug connector (Hole diameter V)

※ Plug connector (Hole diameter V)

Rc ( PT )

Rc ( PT )

N

N

B 1

L

B 1

L

M Brass (C3604)

M Stainless steel (SUS304)

Plug connection parts

Part Number

Opposite side Nominal diameter

Two–sided opposite side B 1

Tapered thread Rc (PT)

Plug connection parts

Part Number

Opposite side Nominal diameter

Two–sided opposite side B 1

Tapered thread Rc (PT)

Matching Plugs

L

Matching Plugs

L

Hole diameter V

N

D 1

Type

No.

Type

No.

Hole diameter V

N

D 1

High flow couplers Tip diameter V = 15

2

15

17

26

47

19

1/4

8A 1/4

High flow couplers Tip diameter V = 15

2

15

17

26

47

19

1/4

8A 1/4

SF120–HFLS (Stainless steel)

F120–HFLS (Brass)

High flow couplers Tip diameter V = 19

3

19

18

32

49

24

3/8

10A 3/8

High flow couplers Tip diameter V = 19

3

19

18

32

49

24

3/8

10A 3/8

E Matching Plugs: F120−HFLP D P.971 . E Use cooling high flow coupler series matching with the diameter size of socket and plug. Please note it's not applicable to combining different sizes. E Matching Joint Plug Connections D P.949

High flow couplers Tip diameter V = 22

4

22

21

35

60

29

1/2

15A 1/2

E Matching Plugs: MISUMI's cooling high flow couplers F120−HFLP (Ex. F120−HFLP2)/SF120−HFLP d Below/ P.972 Nitto's high flow couplers HFL □ P (Ex. HFL2P) E Use cooling high flow coupler series matching with the diameter size of socket and plug. E Matching Joint Plug Connections d P.949 E Guide for Sockets/Plugs d P.951 / 952 / 1195 – 1198 E Use in atmospheric pressure 1.0MPa (10kgf/cm 2 ) or lower. E Keep water temperature under 180°C. E For cooling high flow couplers, there are automatic open/close valves in socket and plug respectively due to the structure of double valves.

E Guide for Sockets/Plugs D P.951 / 952 / 1195 – 1198

E Use in atmospheric pressure 1.0MPa (10kgf/cm 2 ) or lower. E Keep water temperature under 180°C. E For cooling high flow couplers, there are automatic open/close valves in socket and plug respectively due to the structure of double valves.

For male screw joint SF120–HFLP (Stainless Steel)

R ( PT )

For female screw joint F120–HFLM (Brass)

Rc ( PT )

※ Socket connection section

R

R 1

L

L

B

M Brass (C3604) Thread JIS B0203 tapered thread for tubing R (PT)

L

B

M Stainless steel (SUS304)

Socket connection parts

Part Number

Opposite side Nominal diameter

Allen side B

Tapered Screws R(PT)

Socket connection parts

Part Number

Opposite side Nominal diameter

Allen side B

Tapered thread Rc (PT)

Matching Sockets

L

D 1

L

1

Matching Sockets

L

D 1

Type

V

No.

L

Type

V

No.

L

High flow couplers Tip diameter V = 15

2

15

16.5

50

18.5

17

13

1/4

8A 1/4

High flow couplers Tip diameter V = 15

F120–HFLM (Brass)

2

15

16.5

30

18.5

17

1/4

8A 1/4

SF120–HFLP (Stainless Steel)

High flow couplers Tip diameter V = 19

3

19

18

54.5

23

21

13

3/8

10A 3/8

High flow couplers Tip diameter V = 19

3

19

18

31

23

21

3/8

10A 3/8

E Matching Sockets: F120−HFLS D P.971 . E Use cooling high flow coupler series matching with the diameter size of socket and plug. Please note it's not applicable to combining different sizes. E Matching Joint Plug Connections D P.949 E Use in atmospheric pressure 1.0MPa (10kgf/cm 2 ) or lower. E Keep water temperature under 180°C. E For cooling high flow couplers, there are automatic open/close valves in socket and plug respectively due to the structure of double valves. E Guide for Sockets/Plugs D P.951 / 952 / 1195 – 1198

Rc ( PT )

※ Socket connection section

For male screw joint F120–HFLP (Brass)

Part Number SF120–HFLS2 SF120–HFLP2 SF120–TSH 3 SF120–TPM 3

Delivery Quotation

Order

L

L

B

M Brass (C3604)

Socket connection parts

Part Number

Opposite side Nominal diameter

Allen side B

Tapered thread Rc (PT)

Matching Sockets

L

D 1

Type

V

No.

L

High flow couplers Tip diameter V = 15

2

15

16.5

30

18.5

17

1/4

8A 1/4

F120–HFLP (Brass)

High flow couplers Tip diameter V = 19

3

19

18

31

23

21

3/8

10A 3/8

E Matching Sockets: MISUMI's cooling high flow couplers F120−HFLS (Ex. F120−HFLS2)/SF120−HFLS (Ex. SF120−HFLS2) d Above/ P.972 Nitto's high flow couplers HFL □ S (Ex. HFL2S) E Use cooling high flow coupler series matching with the diameter size of socket and plug. E Matching Joint Plug Connections d P.949 E Guide for Sockets/Plugs d P.951 / 952 / 1195 – 1198 E Use in atmospheric pressure 1.0MPa (10kgf/cm 2 ) or lower. E Keep water temperature under 180°C. E For cooling high flow couplers, there are automatic open/close valves in socket and plug respectively due to the structure of double valves.

Part Number F120–HFLS2 F120–HFLM2 F120–HFLP3

Delivery Quotation

Order

971

972

Powered by